1. It adopts luxurious aluminum alloy chassis, which is beautiful in appearance and sturdy in structure; it is equipped with a shock-proof outer packing box, which is convenient for moving and carrying.
2. Built-in industrial computer, using 7" industrial LCD screen, bright colors, large viewing angle; easy to work under strong light. Rich I0 ports, with one RS232, two
USB port; built-in electronic disk, which can store 10,000 pieces of energy meter data.
3. Class D power amplifier with modular design, with high output power, low failure rate and high efficiency.
4. Perfect protection function, with voltage short circuit, current open circuit, power amplifier overheating and other protections.
5. It can test the metering function of the smart meter, including creep, start, two-way basic error, standard deviation, constant calibration, error variation, error curve, combined error
Difference and voltage, current, power error detection functions, etc.
The 62nd to 21st harmonics are superimposed, the amplitude is 40% and the phase can be set freely. Harmonic analysis can also be performed on the output quantity and waveforms can be drawn.
7. Built-in 2x10-7 high-precision constant temperature crystal oscillator, which can test the timing and tariff functions of smart meters, including time calibration, daily timing error, tariff setting and time period switching errors
difference, demand cycle error, demand indication error, etc.
8. The event recording function of the smart meter can be tested, including voltage loss, current loss, phase loss, full voltage loss, power failure, programming, zero reset, switch cover, gate opening, etc.
The freezing function of the table can be tested in a variety of freezing methods.
9. To test the carrier interface (optional) and RS485 interface of the smart meter, it can check the communication protocol consistency of the smart meter.
10. With cost control function test, it supports two types of electric energy meters, local cost control and remote cost control, and can also test trip relays.
11. The device can be equipped with self-test function, which can test the voltage, current, phase, power factor, frequency, output harmonic waveform, power stability and other indicators of the device.
monitor.
Part of the hanging table: 1. Special aluminum alloy structure
2: Each epitope crystal is equipped with a channel I permanent rush interface (multi-function pulse input, 4-channel photoelectric pulse input, 485 communication), which can test the basic error of the meter, creep test, and start test.
Test, communication protocol test, meter internal register test and other functions.
3: Each calibrated meter station is equipped with a dedicated 6-bit meter processor, which can display the basic error, clock, pulse number and relay trip and close instructions. (or built-in three-phase
source)
Technical Indicators
parameter name | main indicators |
---|---|
Accuracy class of the device | Level 0.05, Level 0.1 |
Device standard energy meter rating | Level 0.05 (built-in) |
Voltage range | 3 X 220V/Y 3 x 57.7V/Y 3x380V/A 3x1C0V/A 0-120% range adjustment fineness: 0.01% full scale |
Current range | 0.025A, 0.1A, 1A, 5A, 25A, 100A 0-120% range adjustment fineness: 0.01% |
Phase shift range | 0-360°, adjustment fineness: 0.01° |
Output frequency | 45Hz - 65Hz, adjustment fineness: 0.01Hz |
Indicating instrument accuracy | Voltage: ±02% Current: ±02% Phase: ±0.1° Power: ±02% |
Output waveform distortion | Voltage: <0.5% Current: <0.5% |
output stability | Voltage: <0.05% / 3 minutes Current: <0.05% / 3 minutes Power: ≤0.05% / 120S |
output capacity | Voltage loop: 50VA Current loop: 200VA |
Clock Accuracy | 3X10-7S _ _ |
Minimum starting current | 1mA, accuracy: 5%; starting power: accuracy 5% |
output harmonics | 2 to 21 times |
Device input power | 220VAC, ±10%, 50Hz; maximum power consumption: 800VA |
Shape Indicators
project type | Dimensions: L*H*Dmm³ |
---|---|
three-phase source | 495x230x610mm³ |